LG Brings New Indoor VRF Heat Pump to the US Market, Filling a Void for Urban HVAC Design

New LG Multi V Space

For some time now I have been advocating for an indoor single phase VRF (variable refrigerant flow) split system with a horizontal discharge condensing unit for window, through the wall and/or louver applications. Even though VRF systems have the capability for long refrigerant piping runs for outdoor roof or areaway space, sometimes that space is just not available to designers and contractors. Many condo or coop boards will not allow multi-dwelling building unit owners to put there equipment in common areas like roofs or courtyards. Inevitably, many are forced into using thru-the-wall condensing units in order to have central air conditioning in their residences. As a result, the highest efficiency alternative, VRF,  is not a consideration because a through wall system was not available. Consequently, condo owners and smaller commercial tenants would have to settle for a 12 SEER thru-the-wall condensing unit instead of a 18+ SEER VRF alternative with variable speed compressor for additional partial load efficiency.

LG has answered the call for a single phase through wall option with its new Multi V Space hi-rise VRF solution. This 4.4 ton unit has a front condenser air inlet and outlet that sits flush against an exterior louver. It is designed to operate in turbulent wind conditions, which is often the case in hi-rise buildings in urban settings like Manhattan, San Francisco or Chicago. Condenser air discharge airflow is adjustable in three directions to prevent condenser air short cycling. Service and control access is all through a single interior panel located within the space. Refrigerant piping is flexible with connections at the rear or either side. Unlike the larger commercial 3 phase units, no condenser air discharge ductwork is required indoors. An optional automatic louver can open and close with system interlock to prevent draft in off cycles. The unit is quiet with projected sound power ratings at or below 55 dB(A). At only around 19″ deep, the unit footprint will mean very little floor area loss in an apartment or office.

Although the Multi V Space has been announced in the US, it is only currently available for purchase in Europe and Asia, but will be available in the US market shortly.  Click here for a link to preliminary PDF literature on the equipment.  This unit can be paired with any of LG’s indoor evaporators, both ducted and ductless,  just like its standard outdoor heat pump counterpart. The flexibility of the system should open up a world of options for HVAC design and layout in multi-tenant urban environments where exterior HVAC equipment space is not an alternative. It will be interesting to see if competitors develop a similar alternative once the Multi V  Space hits the market. More on this product as it becomes available.

As always, to keep up to date with what’s new in HVAC technology, visit our website at airideal.com and follow us on Twitter @airideal and at our Facebook page!

Advertisements

VRF System Ratings and Qualifying for Demand Side Incentives

The American Heating and Refrigeration Institute (AHRI) has finally developed a new certification program for variable refrigerant flow multi-zone split air conditioners and heat pumps. In years past, systems manufactured by Mitsubishi, Daikin, LG and the like were unable to qualify for utility rebates and Federal tax incentives because there was no way to rate their efficiency performance. This was primarily because multi-zone ductless and ducted VRF systems had so many potential variations of installed indoor components that it made it nearly impossible to accurately rate SEER (Seasonal Energy Efficiency Rating), EER (Energy Efficiency Ratio) and HSPF (Heating Season Performance Factor). To solve this problem, AHRI came up with this new 2012 certification program. “This certification program covers matched variable refrigerant flow multi-split air-conditioner and multi-split heat pump systems, that comply with either the National Appliance Energy Conservation Act (NAECA) or the Energy Policy Act (EPACT) and use distributed refrigerant technology with cooling and heating capacities for outdoor units from 12,000 Btu/h [3508 W] to 300,000 Btu/h [87,692 W] and indoor units from 5,000 Btu/h [1,462 W] to 60,000 Btu/h [17,538 W]. Each indoor unit is designed to condition a single zone.”

As a result, we can now submit certain combinations of VRF systems to LIPA (utility) for residential and commercial rebate programs. This is great news because VRF systems provide their greatest savings because of their ability to operate at part load capacity. Very rarely will an air conditioning or heating system be required to operate at peak load (outdoor temps at or above 95 degrees F or below 15 degrees F). This is where the variable speed compressors in VRF systems and their ability to shift load from one area to the next comes into play. Although some VRF systems may not be able to achieve the top peak load efficiency ratings that a single or dual speed DX system can, they are considerably more efficient in partial load situations because of their DC inverter driven ability to ramp up and down from 10% to 100%+ of required capacity. Also, because most of these systems utilize electronic expansion valves that allow for an increase or decrease in refrigerant volume flow depending upon load, they have the ability to shift capacity requirements as the cooling or heating load shifts in a space due to environmental factors like solar gain variance (sun movement), occupancy levels and infiltration. This ability also allows for the use of up to 150% of indoor coil versus outdoor coil capacity.  This is something that cannot be done with standard ducted systems unless they have VAV (variable air volume) terminals or are part of a chilled water system.

Ultimately, this is a great win for the VRF industry, energy conscious consumers and VRF system installers.

As always, to keep up to date with what’s new in HVAC technology, visit our website at airideal.com and follow us on Twitter @airideal and at our Facebook page!

VR Technology Becomes Mainstream Solution in Urban Environments


Variable Refrigerant technologies have become a mainstream HVAC application in urban environments over the past decade. The flexibility of unit design and layout configurations has made this a market niche for Air Ideal and other mechanical design/build firms in the New York metropolitan area. With a variety of indoor evaporators for floors, ceilings, walls and concealed spaces, they provide a simple solution for city projects with minimal space considerations for mechanical equipment. For many years SCAV (self contained air-cooled vertical) package units were the dominant city specified systems for individual tenant spaces, but they were notoriously inefficient and provided poor climate control and distribution across spaces with high diversity and multiple loads. Mitsubishi, Daikin and now LG and Fujitsu have all brought commercial products to the US city markets that provide solutions for office, retail, industrial and multi-dwelling residential projects.

These Asian manufacturers have also had the savvy to provide the necessary marketing expertise and design and application software to design/build contractors and engineers so that they can be properly specified, installed and commissioned. Each manufacturer and their individual distributors have been intelligent enough to provide direct training and certification for their equipment through local training and education centers located close to the metropolitan areas being served to further enhance their products diffusion to the marketplace. This also prevents poor installations as the result of lack of product knowledge and technical application inexperience.

The only barrier towards gaining major market share in urban HVAC applications has been the relative cost of these products. Equipment cost, import tariffs and three step distribution have been competitive disadvantages, but as more systems have been specified and installed, the economies of scale are ramping up and making these systems a viable alternative to standard unitary products. The partial load efficiencies of inverter technology from these products has also served as an ROI tool for convincing more owners and developers to include Variable Refrigerant equipment as a green alternative to standard unitary HVAC systems.

As always, to keep up to date with what’s new in HVAC technology, visit our website at airideal.com and follow us on Twitter @airideal and at our Facebook page!